Shop

  • fluidwell_200_85 The F040 is a straight forward temperature indicator with large 26mm (1") high digits. The measuring unit to be displayed below the temperature is simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution! The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.
  • fluidwell_200_85 The F050 is a straight forward pressure indicator with large 26mm (1") high digits. The measuring unit to be displayed below the pressure is simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution! The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.
  • fluidwell_200_85 The F073 is a versatile level indicator with continuous level monitoring feature. It offers the ability to set one low level and one high level alarm value. If desired, an ignore function can be set up to allow for an incorrect level for a certain period of time. The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers. The display shows the actual level, height or percentage, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.
  • fluidwell_200_85 The D090 is a local, panel mount indicator to display the actual process value, range and loop current. The measuring unit to be displayed is simply selected through an alfa-numerical configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user friendly solution! The configuration of Span, offset and number of decimals is done through software functions, without any sensitive dip-switches or trimmers.
  • isoil_logo_200_85 The MS 2500 flanged sensor are well suited for all application and flow ranges. The MS2500 is available in the widest range of diameters. Features; • Accuracy to +/-0.2% of rate from 1 to 33 ft/sec. • Nineteen sizes from 1" to 48" Pipe Diameters. • Flow ranges from 2.37 to 179,400 GPM. • Pressures to 5600 PSI. • Volumetric flow rate measurement independent of fluid viscosity, density and temperature. • No moving parts for zero maintenance. • Bi-directional flow measurement. • No pressure drop through sensor. • Optional Integral ground electrode eliminates grounding rings with plastic piping systems. • Minimal straight pipe run required. • Every sensor is factory wet-calibrated.
  • itt_logo_200_85 Series 100P (diaphragm sensor) for pneumatic and low impulse hydraulics up to 3000 psig system pressure Versatile Nega-Rate® Belleville disc spring pressure switch for a wide range of applications. Specifications • Electrical: Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International • Electrical Connection: 1/2 NPT female conduit connection with terminal block • Pressure Connection: o Wetted Material 1 1/4 NPT Female o Wetted Material 4, 5, 7 and 9 1/2 NPT Female • Temperature Range o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +300°F (-40°C to +149°C) • Media temperature limits change with O-Ring selection • Adjustment: Concealed wrench flat adjustment with range scale • Shipping Weight: Approximately 3 pounds
  • itt_logo_200_85 142P8 NEMA 4X, 7, 9 & 13 Ultra Low Vacuum/Pressure Switch Ultra-low pressure and vacuum to pressure crossover switch. Unique construction using efficient Nega-Rate® Belleville disc spring for stable set points and high proof pressure. Explosion proof enclosure and wide range of wetted materials makes this switch especially well-suited for hazardous or corrosive atmospheres. Specifications • Electrical: Snap action electrical switch listed by Underwriters’ Laboratories, Inc., FM Approval and CSA International • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18” long leads • Pressure Connection: 1/2 NPT Female • Temperature Range* o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -50°F to +250°F (-46°C to +121°C) • Adjustment: Concealed wrench flat adjustment with range scale • Shipping Weight: Approximately 3.5 pounds *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings.
  • itt_logo_200_85 100T NEMA 4X, 7, 9 & 13 Temperature Switch/Internal Adjustment Direct mount adjustable temperature switch for use in hazardous areas. Utilizes efficient Nega-Rate® Belleville spring mechanism and saturated vapor sensor for quick response and narrow deadband. Specifications • Electrical: Snap action electrical switch assembly listed by Underwriters’ Laboratories, Inc., FM Approval and CSA International • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads • Pressure Connection: 1/2 NPT Male; Direct mount • Temperature Range: o Ambient: -40°F to +180°F (-40°C to +82°C) o See Electrical Assembly specification sheet for Temperature Class Ratings. • System Pressure: 1500 psig maximum • Proof Pressure: 2250 psig • Adjustment: Concealed wrench flat adjustment with range scale • Shipping Weight: Approximately 3 pounds
  • itt_logo_200_85 162P NEMA 4X, 7, 9 & 13 Differential Pressure Switch Adjustable high pressure differential switch. Rugged construction with efficient Nega-Rate® Belleville disc spring sensing mechanism. Maintains set point at high system pressure. Available in all stainless steel construction with hermetically sealed electrical assembly for corrosive atmospheres. Specifications • Electrical: Snap action electrical switch assembly listed by Underwriters’ Laboratories, Inc., FM Approval and CSA International • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads • Pressure Connections: 1/4 NPT Female • Temperature Range* o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +300°F (-40°C to +149°C) • Adjustment: External 1/2" hex head Note: Turn clockwise to increase set point; approximately 24 turns through range • Shipping Weight: o Aluminum: Approximately 3 lbs o Stainless Steel: Approximately 7 lbs *Temperature limits change with O-Ring selection. See Electrical Assembly specification sheet for Temperature Class Ratings.
  • itt_logo_200_85 105P/105PP NEMA 1 & 2 Pressure Switch/Miniature Tamper Proof All-purpose miniature tamper proof switch, extremely light weight and durable construction. Has efficient Nega-Rate® Belleville disc spring sensing mechanism. Small size improves vibration and shock resistance. Specifications • Deadband (Differential): The deadband can be selected anywhere from the minimum indicated to a maximum of 45% of the set point. • Electrical Connection: PVC insulated 18 AWG leads 18" long • Pressure Connection: 1/4 NPT Male • Temperature Range* o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +300°F (-40°C to +149°C) • *Temperature limits change with O-Ring selection • Shipping Weight: Approximately 3 ounces
  • pepperl_fuches_200_85 K-System isolated barriers offer an extensive range of intrinsic safety interface modules for many signals and applications – from simple isolators to highly functional modules. Furthermore, the signal conditioners are the perfect choice for general-purpose. Both types of modules can be mounted on the same Power Rail. They are clearly differentiated by color as signal conditioners have grey front labels. K-System modules are available in a variety of housing widths so they easily fit into any cabinet or enclosure. Whether one chooses the 12.5 mm KC-modules or the 20mm and 40mm KF-modules, the electrical and mechanical characteristics of the K-System are maintained.
  • pepperl_fuches_200_85 Z-system zener barriers are available with high density up to 2 channels / 12,5 mm width. Variants with field replaceable fuses provide a convenient means of disconnecting or open-circuiting the instrument loop without interfering with the wiring, making commissioning and maintenance operations much easier.
Go to Top