    TKW FLOW METER Paddle Wheel Flow Meter - Blind Display

    Features:

    • No Programming Required
    • SDR11 PP Butt Weld or NPT Thread, CPVC, PE 100 RC Ends
    • High Accuracy Less than ± 1.0% of Full Scale
    • NPN Pulse+ 4-20mA Output
    • Corrosion Resistant Materials PVC/PP/316SS
    • Low Cost Visual Indication
    • Easy Installation-No Mounting Kits
    • Compact Design • Horizontal or Vertical Installation
    • Size Range ½”- 4” (PVC, PP)
    • Low Pressure Drop
    • NEMA 4X Enclosure
    • Suitable for Corrosive Environments
    • True- Union Design ½” - 2” (Flanged 3”- 4”)
    • Light Weight
  •  

    UltraFlo1000 Series PFA Plastic – All Teflon Ultrasonic Flow Meter

    PFA :
    All Teflon Ultrasonic Flow Meter
    Measures Continuous / Dosing / Pulsating Flow
    All Plastic Ultrasonic Measurement Technology
    Excellent Corrosion Resistance
    High Purity Applications

    Features:

    • Flared Tubing Ends
    • Blind Display
    • Heavy Duty Design; Simple to Install
    • Completely Corrosion Resistant
    • Light Weight
    • Measuring Range (l/m)
      • 3/8"  0.02 to 0.09
      • 1/2"  0.3  to 24
      • 3/4"  0.9 to 60
      • 1"    1.2 to 120
    • Outputs 4-20mA  + Qty 2 Digital outputs , configurable as Pulse and/or alarm output
    • Input  1 Digital usable for dosing start or zero offset
    • Communication Data Interface  (1 wire) alternative RS-485 (2 wire)
    • Power Supply 24Vdc / 3.6 W
    • Low Flow Rates-.02 LPM-0.005 GPM
    • Suitable for Ultra Pure Applications
    • IP65 Enclosure
    • Negligible Pressure Drop
    • Empty Pipe Alarm
    • Ultrapure Flow Design
  •  

    UltraFlo4000 Series All Plastic Ultrasonic Flow Meter

    All Plastic Ultrasonic Flow Meter Measures Continuous / Dosing / Pulsating Flow Ultrasonic Measurement No Moving Parts Ultra Low Flow Applications

    Features:

    • No Moving Parts
    • PVC-CPVC True Union Ends (Option)
    • Heavy Duty Design; Simple to Install
    • Completely Corrosion Resistant
    • Measuring Range
      • 1/2"   0.3 to 21  LPM / 0.8 to 5.5 GPM
      • 3/4"   0.9 to 36 LPM / 0.24 to 9.5 GPM
      • 1"     3.5 to 60 LPM / 0.92 to 15.8 GPM
      • 1 1/4 5.0 to 240 LPM / 1.32 to 63 GPM
    • Maximum Pressure
      • 1/2"   16 bar / 232 psi
      • 3/4"   16 bar / 232 psi
      • 1"     10 bar / 145 psi
      • 1 1/4 10 bar / 145 psi
    • Temperature Range -10 to 80C / -14to 176F
    • Outputs 4-20mA  + Qty 1 Digital Pulse output or empty pipe alarm
    • Input  1 Digital usable for dosing start or zero offset
    • Communication  Data interface  (1 wire) alternative RS-485 (2 wire)
    • Power Supply 24Vdc / 3.6 W
    • Display Flow Rate + Totalizer
    • IP67 Enclosure NEMA 4X
    • Negligible Pressure Drop
    • Empty Pipe Alarm
    • Polysulfone Body Material
  •  

    UltraFlo5000 Series PVDF-PE Ultrasonic Flow Meter

    Measures Continuous / Dosing / Pulsating Flow All Plastic Ultrasonic Measurement Technolog

    Features:

    • ½", ¾", 1"NPT or Threaded Connections
    • Heavy Duty Design; Simple to Install
    • Completely Corrosion Resistant
    • Negligible Pressure Drop
    • Empty Pipe Alarm
    • Measuring Range
      • 1/2"   0.3 to 21  LPM / 0.8 to 5.5 GPM
      • 3/4"   0.9 to 36 LPM / 0.24 to 9.5 GPM
      • 1"     3.5 to 60 LPM / 0.92 to 15.8 GPM
    • Maximum Pressure
      • 1/2"   7 bar / 100 psi
      • 3/4"   7 bar / 100 psi
      • 1"     7 bar / 100 psi
    • Temperature Range -10 to 100C / -14 to 176F
    • Outputs 4-20mA  + Qty 1 Digital Pulse output or empty pipe alarm
    • Input  1 Digital usable for dosing start or zero offset
    • Communication  RS-485 (2 wire)
    • Power Supply 24Vdc / 3.6 W
    • Display Flow Rate + Totalizer
    • IP67 Enclosure NEMA 4X
    • Housing Material PE (Polyethylene) / PVDF (Polyvinylidenfluoride)
  •  

    The UltraPro Ultrasonic level Sensors are 2-Wire loop powered sensors designed provide reliable accurate level measurement, flow monitoring, and volume of liquids in tanks, pits, sumps and open channels. The UltraPro series are very reliable and offer both 4-20mA analog output with HART® protocol or output RS-485 Modbus. Key Applications : Chemical Storage Tanks / Waste Sumps / Bulk Storage / Tanker Truck / Day Tank / Process Tank / Neutralization Tank / Open Channel / Chemical Feed and Clarifier Applications. The UltraPro Series are designed to work with most types of remote instrumentation and provide enhanced functionality such as remote displays and remote monitoring solutions. 

    Features:

    • Accurate Non-Contact Continuous Level Measurement of liquids / Tanks / Sumps / Ranges up to 65 Feet
    • Quick View Display
    • Simple to Program / Easy Adjustment
    • False Echoes Elimination / (Self Teaching)
    • Automatic Temperature Compensation
    • Explosion Proof / Option Available
    • Analog Current output (4 -20mA) with HART® protocol or output RS–485 Modbus
    • Supply voltage 18 to 36 VDC
    • Bright Yellow LED Display
    • Lock-Out Feature
    • IP67
  •  

    Corrosion Resistant PVDF Narrow Beam Technology Simple Programming

    The UltraPro Ultrasonic level Sensors are 2-Wire loop powered sensors designed provide reliable accurate level measurement, flow monitoring, and volume of liquid in tanks, pits, sumps and open channels. The UltraPro series are very reliable and offer both 4-20mA anlog output with HART® protocol or output RS-485 Modbus. Key Applications: Chemical Storage Tanks, Waste Sumps, Bulk Storage, Tanker Truck, Day Tank, Process Tank, Neutralization Tank, Open Channel, chemical feed and clarifier applications. The UltraPro Series are designed to work with most types of remote instrumentation and provide enhanced functionality such as remote displays and remote monitoring solutions. 

    Features:

    • Accurate Non-Contact Continuous Level Measurement of liquids / Tanks / Sumps / Ranges up to 65 Feet
    • NO FOB or Computer Programs Required
    • Completely Corrosion Resistant
    • Industry's Easiest to Program / 2 Clicks
    • Field Adjustable Set-Points Automatic Temperature Compensation
    • Explosion Proof / Class 1 Div 1 Available
    • Analog Current output (4-20mA) with HART® protocol or RS–485 Modbus
    • Supply voltage 18 to 36VDC
    • On Tank / Sump Programming / Under 2 min
  •  

    Battery Operated / 5 years

    Digital LCD Display A

    All Plastic Design Non-Contact Technology

     Applications:

    • Double Walled Tanks
    • Chemical Storage / Chemical Sumps
    • Remote Applications / No Wiring Required
    • Chemical Feed Day Tanks
    • Drums / Totes

    Features:

    • Quick Visual of Level / 10 Point Bar Graph
    • Simple to Ins
    • Wireless Communication to Remote Display Range of 200 feet Red LED Alarm Flashes when level falls within 8 Inches of Max Fill or Low Level
    • Remote Display simply plugs into 120VAC / No Wiring Required
    • Leak Detection PP Buoyancy Switch for Double Wall Tanks
    • 3 Versions / Sensor / Sensor + Leak Detection / Sensor + Leak Detection + Display
    • Comes Factory Programmed or Program in under 2 min in the field
    • All Plastic Corrosion Resistant Enclosure
    • Operating Temperature -10°C to 60°C
    • Long lasting battery / Std 'C' cell Type > 5 Years
    • IP67 , Remote Display IP44 Indoors Only