Shop

  • isoil_logo_200_85 112P NEMA 4X, 7, 9 & 13 Flanged Pressure Switch/Diaphragm Sensor Flanged pressure switch for installations that formerly required a chemical seal with fill fluids. Reliable Nega-Rate® Belleville disc spring sensing mechanism. Redundant seals with venting between seals for alarm or indication. 316 stainless steel body and hermetically sealed, explosion-proof electrical assembly well suited for hazardous or corrosive atmospheres. Specifications • Electrical: Snap action electrical switch assembly listed by Underwriters’ Laboratories, Inc., FM Approval and CSA International • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18” long leads • Pressure Connection: o 1 inch, 1/16 raised face flange per ANSI o B 16.5 - 1998 o Class 150 (150#) o Class 300 (300#) Note: Customer responsible for gasket selection and installation. (Refer to Installation and Operating Instructions supplied with switch) • Temperature Range*: o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +250°F (-40°C to +121°C) • Adjustment: Internal, slotted adjustment with range scale • Shipping Weight: Approximately 4.5 pounds *Limited by gasket material selected
  • 11 SERIES CLAMPED-STYLE SANITARY PRESSURE TRANSMITTERS utilize diffused semiconductor and proven sputtered thin film sensor technology to produce a highly accurate, stable, shock resistant and durable pressure transmitter. They are suited for applications in the food & beverage, dairy, biotechnology and pharmaceutical industries and meet the current 3A standards as well as ASME BPE-2009 and CE compliant. Wetted parts are 316L stainless steel and electropolished to 32 μin Ra or better. Can be cleaned in place (CIP) and steamed in place (SIP).

     
  • itt_logo_200_85 105P/105PP NEMA 1 & 2 Pressure Switch/Miniature Tamper Proof All-purpose miniature tamper proof switch, extremely light weight and durable construction. Has efficient Nega-Rate® Belleville disc spring sensing mechanism. Small size improves vibration and shock resistance. Specifications • Deadband (Differential): The deadband can be selected anywhere from the minimum indicated to a maximum of 45% of the set point. • Electrical Connection: PVC insulated 18 AWG leads 18" long • Pressure Connection: 1/4 NPT Male • Temperature Range* o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +300°F (-40°C to +149°C) • *Temperature limits change with O-Ring selection • Shipping Weight: Approximately 3 ounces
  • itt_logo_200_85 100TC NEMA 4X, 7, 9 & 13 Temperature Switch/Internal Adjustment Remote mount adjustable temperature switch for use in hazardous areas. Utilizes the efficient Nega-Rate® Belleville spring mechanism and saturated vapor sensor for quick response. Specifications • Electrical: Snap action electrical switch assembly listed by Underwriters’ Laboratories, Inc., Factory Mutual and CSA International • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads • Process Connection: 1/2 NPT Male Remote mount. Stainless steel 6' capillary with armor jacket, 10" minimum bendable tubing and 1/2" adjustable gland nut. Optional capillary lengths available. • Temperature Range: o Ambient: -40°F to +180°F (-40°C to +82°C) o See Electrical Assembly specification sheet for Temperature Class Ratings. • System Pressure: 1500 psig maximum • Proof Pressure: 2250 psig • Adjustment: Concealed wrench flat adjustment with range scale • Shipping Weight: Approximately 5 pounds
  • itt_logo_200_85 100T NEMA 4X, 7, 9 & 13 Temperature Switch/Internal Adjustment Direct mount adjustable temperature switch for use in hazardous areas. Utilizes efficient Nega-Rate® Belleville spring mechanism and saturated vapor sensor for quick response and narrow deadband. Specifications • Electrical: Snap action electrical switch assembly listed by Underwriters’ Laboratories, Inc., FM Approval and CSA International • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads • Pressure Connection: 1/2 NPT Male; Direct mount • Temperature Range: o Ambient: -40°F to +180°F (-40°C to +82°C) o See Electrical Assembly specification sheet for Temperature Class Ratings. • System Pressure: 1500 psig maximum • Proof Pressure: 2250 psig • Adjustment: Concealed wrench flat adjustment with range scale • Shipping Weight: Approximately 3 pounds
  • 100J3 Diaphragm Seals for Saddle Weld Process Connections Standard Pressure Rating with Metal Lower Housings Complete with Clean-Out Option Process Connection Sizes 3inch (80mm) and larger All Pipe Schedules per ASME/ANSI B36.10 or B36.19 Maximum Working Pressure Conforms to Pipe Schedule Ratings as calculated by ASME B31.1 Equation "4"@ 100ºF (38ºC) Download Datasheet
  • Standard Features:

    • 1 inch (25.4mm) and larger
    • Process Connections sizes 1 inch through 3 inch (25.4mm to 80mm)
    • ASME/ANSI Flange Ratings up to 2500lb Maximum Working Pressure
    Download Datasheet
  • Standard Pressure Ratings with Metal Lower Housings Process Connection Sizes 1/4 NPTF  through 1 1/2 NPT Maximum Working Pressure 1000, 2000 psig ( 6.9 , 13.80 Mpa) @ 100ºF (38ºC)
    Download Datasheet
  • Standard Pressure Ratings with Metal Lower Housings Process Connection Sizes 1/4" NPTF  through 1 1/2" NPT Maximum Working Pressure 1000,2000 psig ( 6.9 , 13.80 Mpa) @ 100ºF (38ºC) Download Datasheet
  • pepperl_fuches_200_85 The 1000 series Type Z purge system is suitable for Class I, Division 2 to non-hazardous area applications & Class II, Division 2 to non-hazardous area applications.
    • UL, cUL & FM classified
    • Conforms to NFPA 496 and ISA 12.4 standards
    • Enclosure volumes to 450 cu. ft.
    Note: Vents are required for most Type Z purge enclosures

    Type Z purge system models - 1000 series

    1001A: Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS Only 1001B: Class II Enclosure Volumes ≤ 50 ft3 1001C: Class II Enclosure Volumes ≤ 250 ft3 1002: Class I Enclosure Volumes ≤ 15 ft3 1003: Class I Enclosure Volumes ≤ 75 ft3 1004: Class I Enclosure Volumes ≤ 200 ft3 1005: Class I Enclosure Volumes ≤ 450 ft3 11: Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS and WPSA
  • pepperl_fuches_200_85 The 1000 series Type Y purge system is rated for Class I, Division 1 to Division 2 area applications or Class II, Division 1 to Division 2 applications.
    • UL, cUL & FM classified
    • Conforms to NFPA 496 and ISA 12.4 standards
    • Enclosure volumes to 450 cu. ft.
    Note: Vents are required for most Type Y purge enclosures

    Type Y purge system models - 1000 series

    1001A: Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS Only 1001B: Class II Enclosure Volumes ≤ 50 ft3 1001C: Class II Enclosure Volumes ≤ 250 ft3 1002: Class I Enclosure Volumes ≤ 15 ft3 1003: Class I Enclosure Volumes ≤ 75 ft3 1004: Class I Enclosure Volumes ≤ 200 ft3 1005: Class I Enclosure Volumes ≤ 450 ft3 11: Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS and WPSA
  • 1000 SERIES NOSHOK DIGITAL PRESSURE GAUGES are designed to exceed the industry’s most demanding application requirements. Using the latest in reliable ceramic thick film strain gage technology combined with low power electronics, these gauges are accurate, stable and extremely reliable. The 1000 Series gauges are ideally suited for local indication.

Title

Go to Top