Fluidwell

The company is structured in three business units:
Fluidwell – Accurate Liquid Management – for displays,
Fluidwell Instrumentation – Process Instrumentation – for sensor instrumentation
ProcessMonitor – Remote Location Surveillance – for remote process monitoring.

Since 1993, the display business unit has established a name in innovative and original contributions to the development of flow computers, flow rate / totalisers, batch controllers, indicators and monitoring systems. Most of our products are ATEX and IECEx certified for use in hazardous areas.
This has resulted in a wide and flexible product matrix of standard products with an extensive range of options.
We can produce over 200.000 different versions!

  • fluidwell_200_85 The F490 is a versatile, loop powered Multi Purpose Indicator which displays the actual process value, range and loop current. Besides the focus on level, temperature and pressure applications, the F490 can also work with other measuring units, such as %, mA, RPM and more. Therefore, the F490 is a versatile indicator that suits many applications. At the F490, the input circuit is separated from the backlight circuit. It is designed in such way that it does not influence the intrinsically safe circuit to which it is connected. The F490 accepts 4 - 20mA input signals from a wide range of process instruments, including flow (linear or square root), level, pressure and temperature transmitters. All these process parameters can be displayed in their own engineering units. Thanks to its ruggedness, the F490 withstands extreme weather conditions such as rain, snow, sun, sandy deserts, salty atmospheres and temperatures between -40°C/-40°F and +80°C/+178°F without the need for expensive protective cabinets. Moreover, all products in the F-series are robust by design: even a truck can stand on them.

    Hazardous area information

    The F490 is certified according ATEX, IECEx and CSA for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). ATEX markings: Gas: II 1 G Ex ia IIC T4 Ga Dust: II 1 D Ex ia IIIC T100°C Da IECEx markings: Gas: Ex ia IIC T4 Ga Dust: Ex ia IIIC T100°C Da CSA c-us markings: IS Class I/II/III, Division 1, Groups A to G. Ex ia IIC / Class 1 Zone 0 AEx ia IIC T4.  
  • fluidwell_200_85
    The E115 has been developed for applications where the direction of flow is an issue. Applications can be found by loading and unloading of ships where one bi-directional flowmeter is used. Another application is the correction of back-flow due to shocks in a pipeline caused by piston pumps or valve behavior. It is required to offer two pulse signals from the flowmeter which are 90° or 270° degrees out of phase.
    The E-series distinguishes itself by its quality and functionality driven European design and manufacturing. It is more than fulfilling the rules for explosion proof design, it is about safety during the daily operation. Often, the environment is much tougher than the explosion proof requirements demand. Thus dangerous conditions may be experienced due to a broken enclosure or a poorly made flame path. Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven explosion proof flow rate indicator / totalizer.

    Features:

    • Explosion proof according ATEX, IECEx, FM and CSA C-US.
    • Aluminum or high grade stainless steel Ex d enclosure.
    • Easy installation with the spacious chamber and plug & play connectors.
    • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
    • Detects flow direction with quadrature signal inputs.
    • Key information at a glance as the display shows forward & reverse flow rate, forward & reverse total, accumulated total count up and count down ref. flow direction, measuring units and a flow rate indicating speedometer.
    • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
    • 7 digit flow rate / total and 11 digit accumulated total.
    • Bright LED backlight.
    • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
    • Auto backup of settings and running totals.
    • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
    • Various accessories are available for this product.

    Hazardous area information:

    • The E-Series are ATEX, IECEx, FM and CSA C-US certified for an ambient temperature range of -40°C to +70°C (-40°F to +158°F).
  • fluidwell_200_85
    The F110 flow transmitter is the most popular model in our range of flow rate indicators / totalizers, complete with pulse and analog output signals. Even demanding applications are catered for with our base unit configuration.
    The display shows flow rate, total and accumulated total. On-screen engineering units are easily configured from a comprehensive selection.

    Advantages

    • Robust IP66, IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it!
    • Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications
    • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all!
    • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors

    Features

    • Analog and pulse outputs
    • Displays total and flow rate simultaneously
    • Large digit selection for flow rate or total
    • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits
    • Total - resettable: seven 17mm (0.67") digits
    • Accumulated total - not resettable: eleven 8mm (0.31") digits
    • Separate engineering units for flow rate and total on the display
    • Remote control input to reset total or to lock the "clear total" button
    • LED backlight
    • Auto backup of settings and running totals in EEPROM memory
    • Ambient temperature: -40°C to +80°C (-40°F to 176°F)
    • Various accessories are available for this product
    • The F-Series is so rugged, even a truck can stand on it!

    Applications

    • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).
    • Liquid flow measurement where re-transmission of the flow rate and/or totalizer functions or serial communication is required. Alternative basic model: F070. Alternative basic models: F010, F011, F012, F014. Alternative advanced models: F112, F113, F118 or the D-Series basic DIN panel mount indicators.
  • fluidwell_200_85 The D016 is a loca,l panel mount indicator with linearization to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however can not be reset to zero. In addition to the average K-Factor or Span, eight linearization points can be entered with there frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flowrange. Even for very low frequency applications is catered for. This linearization affects all displayed information as well as the pulse output.
  • fluidwell_200_85 The F197 is a manual set-point generator. The operator enters an analog or a scaled output value or a percentage which will be transmitted as a (0)4 – 20mA or 0 – 10V DC signal to a control device. If available, the F197 can also display the measured actual process value. However, there is no direct control relationship between the input and output value. Further, one low and one high alarm value can be set with an alarm ignore function to monitor the process. The display shows the pre-set value, actual value and status simultaneously. On-screen engineering units are easily configured from a comprehensive selection.
  • fluidwell_200_85 The F093 is a local indicator to monitor the tachometer engine speed with running hours simultaneously. The running hours can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated running hours however cannot be reset to zero.
  • fluidwell_200_85 he D030 is a straight forward but basic, panel mount batch controller. The operator can enter a batch quantity easily or execute repeating batches. During the batch, the preset value is displayed as well as the batched (or remaining) quantity and the units of measurement. The automatic self-learning overrun correction will ensure an accurate result each batch again.
  • fluidwell_200_85 The D016 is a local panel mount indicator / transmitter with linearization to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however cannot be reset to zero. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range. Even for very low frequency applications is catered for. This linearization affects all displayed information as well as the pulse output.
  • fluidwell_200_85 The D013 is a versatile, panel mount flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the facility to set one low flow rate and one high flow rate alarm value. If desired, a delay function can be set up to allow for an incorrect flow rate for a certain period of time.
  • fluidwell_200_85 The F195 has been developed for the valve position indication and monitoring in hydraulic systems. By using a bi-directional flow meter to measure the volume displaced by the actuator, an accurate position of the system is calculated. The display shows the position as a percentage as well as with the text "open" and "closed" for the minimum and maximum positions. As standard, the analog output mirrors the percentage displayed which can be used to transmit the valve position. The usual difficulties encountered in such applications include: very low flows, vibration, and thermal expansion of the oil and high ambient temperatures.
  • fluidwell_200_85 The D074 is a basic, panel mount level / pump controller that works with a pre-set value and two switch points to control a pump or valve. The low and high level switch points are entered as a percentage of the pre-set value to switch the device on / off. For pump control applications, the function can be inverted to empty a well. A stable level within a hysteresis around the pre-set value is the result.  
  • fluidwell_200_85 The F153 is a versatile pressure indicator featuring continuous pressure monitoring. It offers the ability to set two low and two high pressure alarm values. If desired, an ignore function can be set up to allow for an incorrect temperature for a certain period of time. Up to five outputs are available to transmit alarm conditions and actual pressure. The display shows the actual pressure, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.

Title

Go to Top