Fluidwell

  • fluidwell_200_85 The F018 is a local indicator / transmitter with linearization that displays the actual flow rate, resettable total and non-resettable accumulated total. The F-Series is known worldwide as a range of user-friendly indicators. The F018 is even more impressive. The HART communication allows you to communicate in an easy way with smart "DD enabled host" systems. In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range, even for very low frequency applications. This linearization affects all displayed information as well as the signal outputs.
  • fluidwell_200_85
    The F110 flow transmitter is the most popular model in our range of flow rate indicators / totalizers, complete with pulse and analog output signals. Even demanding applications are catered for with our base unit configuration.
    The display shows flow rate, total and accumulated total. On-screen engineering units are easily configured from a comprehensive selection.

    Advantages

    • Robust IP66, IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it!
    • Intrinsically Safe available - ATEX and IECEx approval for gas and dust applications
    • Programming can be done by your own crew, with the sensible menu-driven structure, saving cost and irritation. Know one, know them all!
    • Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors

    Features

    • Analog and pulse outputs
    • Displays total and flow rate simultaneously
    • Large digit selection for flow rate or total
    • Flow rate: seven 17mm (0.67") or 8mm (0.31") digits
    • Total - resettable: seven 17mm (0.67") digits
    • Accumulated total - not resettable: eleven 8mm (0.31") digits
    • Separate engineering units for flow rate and total on the display
    • Remote control input to reset total or to lock the "clear total" button
    • LED backlight
    • Auto backup of settings and running totals in EEPROM memory
    • Ambient temperature: -40°C to +80°C (-40°F to 176°F)
    • Various accessories are available for this product
    • The F-Series is so rugged, even a truck can stand on it!

    Applications

    • The F-Series is your first and best choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmospheres and temperatures between -40°C up to +80°C (-40°F up to 176°F).
    • Liquid flow measurement where re-transmission of the flow rate and/or totalizer functions or serial communication is required. Alternative basic model: F070. Alternative basic models: F010, F011, F012, F014. Alternative advanced models: F112, F113, F118 or the D-Series basic DIN panel mount indicators.
  • fluidwell_200_85 The F120 single loop controller has been designed to offer outstanding control performance and provide a reliable solution for a wide variety of flow control applications. The single loop flow controller accepts most pulse inputs from flow meters and has a 4 - 20 mA output for controlling a valve or pump. The F120 is part of the Fluidwell process controller family and is the alternative for local control loops.
  • fluidwell_200_85 The F126-EG flow computer has been developed to calculate corrected gas volume at normal conditions. The corrected volumetric flow is calculated by measuring the uncorrected volumetric flow, actual line temperature and pressure which are processed with the equations stored in the flow computer. A compressibility factor can be set to approach a real gas behavior. The reference conditions can be defined as desired (e.g. 15°C or 60°F and 1.013 bar). The display shows the compensated flow rate, total, accumulated total and the actual line temperature and pressure. On-screen engineering units like Nm³ are easily configured from a comprehensive selection.
  • fluidwell_200_85 The F141 incorporates two (2) completely separated temperature indicators in one enclosure. There is no relationship between the inputs, even different measuring units can be used. The measuring unit is displayed together with the input channel information A or B. The F141 can be set to show the selected information manually or with an automatic toggle function.
  • fluidwell_200_85 The F073 is a versatile level indicator with continuous level monitoring feature. It offers the ability to set one low level and one high level alarm value. If desired, an ignore function can be set up to allow for an incorrect level for a certain period of time. The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers. The display shows the actual level, height or percentage, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.
  • fluidwell_200_85 The F010 is a local weather-proof indicator with large 26mm (1”) high digits which displays the actual flow rate. The measuring and time unit to be displayed below the flow rate are simply selected through an alphanumeric configuration menu. The configuration of K-factors or Span and number of decimals is done through software functions without any sensitive DIP-switches or trimmers.
  • fluidwell_200_85 The F490 is a versatile, loop powered Multi Purpose Indicator which displays the actual process value, range and loop current. Besides the focus on level, temperature and pressure applications, the F490 can also work with other measuring units, such as %, mA, RPM and more. Therefore, the F490 is a versatile indicator that suits many applications. At the F490, the input circuit is separated from the backlight circuit. It is designed in such way that it does not influence the intrinsically safe circuit to which it is connected. The F490 accepts 4 - 20mA input signals from a wide range of process instruments, including flow (linear or square root), level, pressure and temperature transmitters. All these process parameters can be displayed in their own engineering units. Thanks to its ruggedness, the F490 withstands extreme weather conditions such as rain, snow, sun, sandy deserts, salty atmospheres and temperatures between -40°C/-40°F and +80°C/+178°F without the need for expensive protective cabinets. Moreover, all products in the F-series are robust by design: even a truck can stand on them.

    Hazardous area information

    The F490 is certified according ATEX, IECEx and CSA for use in Intrinsically Safe applications with an ambient temperature of -40°C to +70°C (-40°F to +158°F). ATEX markings: Gas: II 1 G Ex ia IIC T4 Ga Dust: II 1 D Ex ia IIIC T100°C Da IECEx markings: Gas: Ex ia IIC T4 Ga Dust: Ex ia IIIC T100°C Da CSA c-us markings: IS Class I/II/III, Division 1, Groups A to G. Ex ia IIC / Class 1 Zone 0 AEx ia IIC T4.  
  • fluidwell_200_85 The E018 is one of the top models in our range of explosion proof flow computers. In addition to the average K-Factor, 16 linearization points can be entered. The unit will interpolate between these points greatly enhancing accuracy in any flow range. Moreover, a continuous flow rate monitoring feature is available with high and low flow rate alarm values and four alarm outputs.
  • fluidwell_200_85
    The E115 has been developed for applications where the direction of flow is an issue. Applications can be found by loading and unloading of ships where one bi-directional flowmeter is used. Another application is the correction of back-flow due to shocks in a pipeline caused by piston pumps or valve behavior. It is required to offer two pulse signals from the flowmeter which are 90° or 270° degrees out of phase.
    The E-series distinguishes itself by its quality and functionality driven European design and manufacturing. It is more than fulfilling the rules for explosion proof design, it is about safety during the daily operation. Often, the environment is much tougher than the explosion proof requirements demand. Thus dangerous conditions may be experienced due to a broken enclosure or a poorly made flame path. Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven explosion proof flow rate indicator / totalizer.

    Features:

    • Explosion proof according ATEX, IECEx, FM and CSA C-US.
    • Aluminum or high grade stainless steel Ex d enclosure.
    • Easy installation with the spacious chamber and plug & play connectors.
    • Cost saving with an easy to install, 1” NPT thread for direct flowmeter mounting.
    • Detects flow direction with quadrature signal inputs.
    • Key information at a glance as the display shows forward & reverse flow rate, forward & reverse total, accumulated total count up and count down ref. flow direction, measuring units and a flow rate indicating speedometer.
    • Easy K-factor and engineering unit configuration for volumetric or mass. Learn more with this interactive tutorial.
    • 7 digit flow rate / total and 11 digit accumulated total.
    • Bright LED backlight.
    • Easy configurable via PC with free downloadable remote configuration tool and special communication cable (ACE01/02/06/07).
    • Auto backup of settings and running totals.
    • Ambient temperature: -40°C to +70°C (-40°F to 158°F).
    • Various accessories are available for this product.

    Hazardous area information:

    • The E-Series are ATEX, IECEx, FM and CSA C-US certified for an ambient temperature range of -40°C to +70°C (-40°F to +158°F).
  • fluidwell_200_85 The D074 is a basic, panel mount level / pump controller that works with a pre-set value and two switch points to control a pump or valve. The low and high level switch points are entered as a percentage of the pre-set value to switch the device on / off. For pump control applications, the function can be inverted to empty a well. A stable level within a hysteresis around the pre-set value is the result.  
  • fluidwell_200_85 The D074 is a basic, panel mount level / pump controller that works with a pre-set value and two switch points to control a pump or valve. The low and high level switch points are entered as a percentage of the pre-set value to switch the device on / off. For pump control applications, the function can be inverted to empty a well. A stable level within a hysteresis around the pre-set value is the result.  

Title