Double-Sided No Filling Required Visual Pressure Range Markers Corrosion Resistant
Features:
- Heavy Duty / Double Sided
- Suitable for Corrosive Environments
- Dual Scales Heavy
- Duty Design
- 3 Range Tabs / Red / Yellow / Green
- Large 2½" Color Display
- High Accuracy / ±0.75 %
- Factory Pre-Filled
- Glycerin (Std) / Silicone (Opt)
- Visual Pressure Ranges
- Simple to Install
- Perfect Mate for Plastic Isolators
Specifications:
Dial Diameter Large 2½" Face / Big Numbers / Clear Markers Mounting Direct Mount / Bottom Connection Housing Polypropylene Lens High Impact Polycarbonate Dial Red & Black Scale White Background / dial arc 270° Measuring Principle Bourdon Tube / SS316 / Brass Movement SS316 / Brass Gauge Red / Yellow / Green / Movable Plastic Markers Pressure Range Pointers Fitted on the Bezel Connection ¼" (M) NPT / G Type / 316 SST Filling Glycerin / Silicone (Opt) Accuracy ±0.75% Operating temperature Max. Working Temp / PP - 180°F Pressure Range* Standard Ranges / 0-60 / 0-100 / 0-160 psi (Second Scale: kPA) Other units available bar / MPa - Pressures up to 1500 psi available
DXC Over-The-Side Immersion Heaters feature copper sheathed elements and are typically used for heating water or water solutions that will not corrode copper. They are ideal where easy removal of the heater for cleaning or inspection is required. The DXC is available in single phase or three phase with single element or three element configurations. DXI Over-The-Side Immersion Heaters feature incoloy® sheathed elements, while the DXS features steel sheathed elements. They are typically used in water rinse tank heating applications where contaminants that would be corrosive to copper are present. They are also suitable for oil based solutions and other chemical solutions that are not corrosive to incoloy® (DXI) or steel (DXS). They are ideal where easy removal of the heater for cleaning or inspection is required. The DXI and DXS are available in single phase or three phase with single element or three element configurations. DXN and DXT Over-The-Side Immersion Heaters feature high grade inconel® (DXN) or titanium (DXT) sheathed elements and are typically used in liquid heating applications where copper, stainless or incoloy® are unsuitable because the solution being heated would be corrosive to these materials. They are ideal where easy removal of the heater for cleaning or inspection is required. The DXN is available in single phase or three phase with single element or three element configurations and the DXT is available in single phase with single element configuration
Moore Industries’ PAC and PAV Ac Current and Voltage Transducers accept an ac current (PAC) or ac voltage (PAV) input. They provide a highly accurate (±0.25% of rated output) dc current output. The PAC and PAV respond to the average value of the input signal and are calibrated to indicate the RMS value.
PP1H and PP2H Peristaltic Pump Chemical Feed Prepackaged Systems . SELF PRIMING WITH BUILT IN SPILL AND LEAK PREVENTION The PP1H and PP2H (dual pump model) an ideal choice for hard-to-handle chemicals such as sodium hypochlorite, hydrogen peroxide or viscous polymers. Flow rates from .004 to 98 gallons per hour (with dual pump-head option.)
Environment One's standard Generator Gas Analyzer (GGA) can also be supplied in a portable configuration. The PGA incorporates the same hydrogen gas sensor/analyzer and system electronics found in our other hydrogen gas purity systems. The PGA is specifically intended for use in non-hazardous environments and/or as an emergency back-up in the event a power plant's primary purity monitoring system is compromised.
Self-regulating heating cables consist of two parallel bus wires embedded in a networked plastic heating element, doped with surrounding carbon particles. If the temperature increases during operation, the plastic expands due to molecular expansion and the distance between the carbon particles increases. Resistance increases and output drops. When it cools down, this process is reversed and output increases.
This physical property provides several benefits, including the ability to overlap the self-regulating cable and installation without the requirement of a temperature cut-out device.
Benefits:
Series 100P (diaphragm sensor) for pneumatic and low impulse hydraulics up to 3000 psig system pressure
Versatile Nega-Rate® Belleville disc spring pressure switch for a wide range of applications.
Specifications
• Electrical: Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International
• Electrical Connection: 1/2 NPT female conduit connection with terminal block
• Pressure Connection:
o Wetted Material 1 1/4 NPT Female
o Wetted Material 4, 5, 7 and 9 1/2 NPT Female
• Temperature Range
o Ambient: -40°F to +180°F (-40°C to +82°C)
o Media: -40°F to +300°F (-40°C to +149°C)
• Media temperature limits change with O-Ring selection
• Adjustment: Concealed wrench flat adjustment with range scale
• Shipping Weight: Approximately 3 pounds