  • itt_logo_200_85 Series 100P (diaphragm sensor) for pneumatic and low impulse hydraulics up to 3000 psig system pressure Versatile Nega-Rate® Belleville disc spring pressure switch for a wide range of applications. Specifications • Electrical: Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International • Electrical Connection: 1/2 NPT female conduit connection with terminal block • Pressure Connection: o Wetted Material 1 1/4 NPT Female o Wetted Material 4, 5, 7 and 9 1/2 NPT Female • Temperature Range o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +300°F (-40°C to +149°C) • Media temperature limits change with O-Ring selection • Adjustment: Concealed wrench flat adjustment with range scale • Shipping Weight: Approximately 3 pounds
  • itt_logo_200_85 Series 117P Sanitary Pressure Switch This field adjustable, compact pressure switch is intended for low- to mid-range process applications. The Tri-Clamp® compatible, polished, process connection makes this switch ideal for food, beverage and other sanitary services. Set point stability and vibration resistance are a function of the Nega-Rate® Belleville disc spring. This unit features 316 stainless steel construction, an explosion-proof/hermetically sealed electrical assembly, 18" standard free leads and SPDT or DPDT electrical forms and a wetted material surface polish of 9 - 11 micro inch Ra (0.23 - 0.28 micron Ra).† Specifications • Electrical: Snap action electrical switch listed by Underwriters’ Laboratories, Inc., FM Approval and CSA International • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads • Pressure Connection: 1 1/2" sanitary fitting mates with Tri-Clamp® fitting† • Temperature Range o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +250°F (-40°C to +121°C) • Adjustment: Internal, slotted adjustment with range scale • Shipping Weight: Approximately 2 pounds
  • itt_logo_200_85 Series 200P NEMA 4 & 13 Pressure Switch/Internal Adjustment Versatile Nega-Rate® Belleville disc spring pressure switch for a wide range of applications. Series 200P (piston sensor) for hydraulic applications up to 10000 psig system pressure. Specifications • Electrical: Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International • Electrical Connection: 1/2 NPT female conduit connection with terminal block • Pressure Connection: Wetted Material 1 1/4 NPT Female • Temperature Range*: o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +300°F (-40°C to +149°C) *Temperature limits change with O-Ring selection • Adjustment: Concealed wrench flat adjustment with range scale • Shipping Weight: Approximately 3 pounds
  • eastech_logo_200_85 SewerWatch the First Mobile App for Wastewater Infrastructure
  • moore_logo_200_85

    Functional Safety Frequency-to-DC Transmitter with Display

    The SFY Functional Safety SIL 3 capable Frequency-to-DC Transmitter with Display is part of Moore Industries’ FS Functional Safety Series. It monitors frequency, period, high or low pulse width, and contact closure signals and converts the input signal to a proportional, input-to-output isolated 4-20mA output ready for direct interface with a Safety System, readout instrument, recorder, PLC, DCS, SCADA system. The 2-wire (loop-powered) SFY is ideal for use in your Safety Instrumented System (SIS) in a wide range of process and factory automation monitoring applications:

    Applications:

    • Turbine Tachometer Generators
    • Turbine Flow Meters
    • Magnetic Pickups
    • Dry Contact Closures
    • Variable Frequency Drives
    • Rotating Equipment
    • Pulse and Frequency Output Transducers
    • Motor and Conveyor Speed

    Features:

    • exida certified to IEC 61508:2010. Certified by exida to IEC 61508 for systematic integrity up to SIL 3 and for random integrity up to SIL 2. This means that an SFY is approved for single use in Safety Instrumented Systems (SIS) up to SIL 2 and in a redundant architecture (1oo2, 2oo3, etc.) up to SIL 3.
    • Comprehensive FMEDA certified safety data. Upon request, exida-certified FMEDA data is available for a functional safety practitioner to use in determining the SFY’s applicability in specific safety-related applications.
    • Exceptional accuracy and long-term stability. Typical accuracy is ±0.025% of span with up to 5 years between scheduled calibrations.
    • Sets up in minutes with PC software. You can choose, and then view to confirm, all application specific operating parameters.
    • Versatile input choices. Measures frequency ranges between an amazingly low 0.005Hz up to 25kHz; periods from 40microseconds to 200sec; and pulse widths from 0.2msec to 200 seconds.
    • Programmable moving average filter. Minimizes measurement instability caused by the effects of bent turbine blades and other frequency variations.
    • User-configurable display. A 5-digit LCD shows the process variable in selectable engineering units.
    • Input-to-output isolated and RFI/EMI protected. Resistant to unpredictable ground loops and the harmful effects of plant and equipment “noise”.
  • pepperl_fuches_200_85 The K-system comprises signal conditioners for signal transfer between control system and safe area as well as isolated barriers for communication with field devices in hazardous areas. They are preferred for these kinds of mixed applications. Wide range of isolated barriers and signal conditioners for mixed applications Modules for universal power supply Reduced wiring by Power Rail Removable terminals Many modules with marine approvals and SIL assessment
  • pepperl_fuches_200_85 The SC-system is a signal conditioner product family for applications without hazardous areas on the field side. Modules for analog and digital signals Transmitter power supplies, isolated amplifiers, passive isolators, signal converters, and switch amplifiers 24 V DC supply Reduced wiring effort due to Power Bus
  • eastech_logo_200_85 VANTAGE 4800 Single & Multipath Spool Construction. The Engineering Team at Eastech believed that in order to absolutely meet all of the requirements of AWWA/ANSI C750–03, a flowmeter had to be designed that not only adhered to every section of the Standard, but also eliminated any possibility of improper installation, inaccurate velocity measurements, and less than adequate calibration procedures. A flowmeter, in order to meet these requirements, would have to possess the following features: Factory aligned spoolpiece sensors for guaranteed installed accuracy High accuracy flow measurement under disturbed flow profiles Advanced electronic meters with onboard dataloggers NIST traceable calibration under actual operating conditions  
  • moore_logo_200_85 SIY PC-Programmable Signal Isolator/Converter combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy, and ease of use. The highly versatile SIY programs to accept a wide range of current or voltage inputs. It outputs an isolated, proportional, 4-20mA signal. As a fl exible analog/digital hybrid, this 2-wire (loop-powered) transmitter programs in seconds to handle a wide range of important signal interface applications.
  • moore_logo_200_85

    SLD Functional Safety Programmable Loop Display

    Moore Industries’ universal SLD PC-Programmable Functional Safety Loop Display features a large integral display that shows real-time process status in mA, percent, or any designated 5-character Engineering units (EGU). The SLD is part of Moore Industries’ FS Functional Safety Series products. It is certified by exida as a SIL3 capable, non-interfering device for use in a safety loop. The SLD Functional Safety Programmable Loop Display is the perfect solution to accurately and reliably display process status in a safety loop:

    Features:

    • SIL3 Capability. The SLD is certifi ed by exida for non-interference in a safety loop. (It is not SIL3 assessed or certifi ed to be used as part of the safety function).
    • Easy-to-read, customizable display. The SLD’s independently confi gured display features two rows of large characters that can be clearly read in the fi eld and set to display any EGU.
    • 360° fl exible mounting. When placed into one of our housings, the SLD can be mounted at any angle in nearly any environment.
    • Low voltage drop. Loop-powered by less than 2.3 Volts, the SLD can even be installed on burdened loops.
    • Loop Maintenance Zener Diode Option. Allows the SLD to be removed from the loop for maintenance without interrupting your safety function.
    • Custom and square root curves. Select a square root or linear curve from the library, or create your own. Use our software to input a table in one EGU and have the PC program convert it into a different EGU for display.
  • moore_logo_200_85 The universal SPA2 Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. Very versatile, they accept a signal input from transmitters, temperature sensors and a wide array of other monitoring and control instruments
  • moore_logo_200_85 The universal SPA2IS Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. Very versatile, they accept signal inputs from transmitters and temperature sensors that are located in hazardous areas where the method of protection implemented by the plant or facility is Intrinsic Safety.