  • moore_logo_200_85 Device Couplers provide easy and practical mechanisms for implementing fieldbus systems. TRUNKGUARD Series 300 Device Couplers (TG300) simplify the use of fieldbus devices in Zone 1 by allowing “live” access for maintenance and eliminating the need for Exd junction boxes. The TG300 Series offers our patented Automatic Segment Termination feature and a key-operated magnetic interlock which permits one spur at a time to be de-energized and worked on without shutting down the entire segment.
  • moore_logo_200_85 The CPMS Cathodic Protection Monitoring System monitors above and below ground impressed current cathodic protection systems to ensure that proper corrosion protection is in place and operating at the right levels. Part of Moore Industries’ NET Concentrator System® family of intelligent distributed I/O, the CPMS monitors the critical current and voltage levels of one or two transformer rectifi ers used in cathodic protection systems.
  • moore_logo_200_85 The rugged IPF Field-Mounted Current-to-Pressure Transmitter is designed specifically for installation in harsh environments. The two-wire IPF accepts a 4-20mA or 10-50mA input. It converts the input to a 3-15psig, 0.2-1bar, 15-3psig or 1-0.2bar pneumatic output signal, or to a wide variety of other commonly used pneumatic outputs (see Specifications for details). This versatility allows the IPF to interface with just about any kind of process control instrumentation including chart recorders, data loggers, panel meters, multiplexers, controllers and computers. The IPF can either be surface-mounted or mounted directly on a two-inch (vertical or horizontal) pipe. Two different types of housings are offered. The standard WP housing provides 1/2-inch NPT female wire entry threads while the metric WPM housing provides M20X1.5 female wire entry threads. The IPF transmitter is also available with an optional coalescing filter/regulator that combines both an air filter and a miniature supply line regulator. For more information on
  • moore_logo_200_85 The D-BOX® accommodates temperature, pressure, level and fl ow transmitters, meters, indicators, analyzers, integrators, and many other head-mount and hockey-puck instruments.
  •     DXC Over-The-Side Immersion Heaters feature copper sheathed elements and are typically used for heating water or water solutions that will not corrode copper. They are ideal where easy removal of the heater for cleaning or inspection is required. The DXC is available in single phase or three phase with single element or three element configurations. DXI Over-The-Side Immersion Heaters feature incoloy® sheathed elements, while the DXS features steel sheathed elements. They are typically used in water rinse tank heating applications where contaminants that would be corrosive to copper are present. They are also suitable for oil based solutions and other chemical solutions that are not corrosive to incoloy® (DXI) or steel (DXS). They are ideal where easy removal of the heater for cleaning or inspection is required. The DXI and DXS are available in single phase or three phase with single element or three element configurations. DXN and DXT Over-The-Side Immersion Heaters feature high grade inconel® (DXN) or titanium (DXT) sheathed elements and are typically used in liquid heating applications where copper, stainless or incoloy® are unsuitable because the solution being heated would be corrosive to these materials. They are ideal where easy removal of the heater for cleaning or inspection is required. The DXN is available in single phase or three phase with single element or three element configurations and the DXT is available in single phase with single element configuration
  • flomotion_logo_200_85 2001V Series Peristaltic Pump Systems INDUSTRIAL HOSE PUMP. Exceptional self-priming capabilities make the 2001V Series an ideal choice for hard-to-handle chemicals such as sodium hypochlorite, hydrogen peroxide or viscous polymers. Flow rates to 50.2 gallons per hour.
  • eastech_logo_200_85 The Vantage 2200 is a state-of-the-art microprocessor-based ultrasonic transmitter utilized for measurement of both liquid level and flow in open channels. The 2200 is equipped, as standard, with an internal data logger. More than 70 standard flow equations for flumes, weirs and open flow nozzles are stored in non-volatile memory. Dual sensors can be input to a single set of electronics for dual weir/flume or bar screen level applications. The Vantage 2200 is designed to be extremely user-friendly with an easy to read 20 character alphanumeric, self-prompting display and a menu-driven programming guide.
  • fluidwell_200_85 The D013 is a versatile, panel mount flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the facility to set one low flow rate and one high flow rate alarm value. If desired, a delay function can be set up to allow for an incorrect flow rate for a certain period of time.
  • fluidwell_200_85 The D016 is a local panel mount indicator / transmitter with linearization to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however cannot be reset to zero. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range. Even for very low frequency applications is catered for. This linearization affects all displayed information as well as the pulse output.
  • fluidwell_200_85 he D030 is a straight forward but basic, panel mount batch controller. The operator can enter a batch quantity easily or execute repeating batches. During the batch, the preset value is displayed as well as the batched (or remaining) quantity and the units of measurement. The automatic self-learning overrun correction will ensure an accurate result each batch again.
  • fluidwell_200_85 The F093 is a local indicator to monitor the tachometer engine speed with running hours simultaneously. The running hours can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated running hours however cannot be reset to zero.
  • ISOIL MS600 Magnetic Flowmeter Features • Accuracy to +/-0.4% • Low cost. • Five sizes from 1/8" to 3/4" Pipe Diameters. • Flow ranges from 0.03 to 50 GPM. isoil_logo_200_85 • Standard Pressure: 230 PSI. • Volumetric flow rate measurement independent of fluid viscosity, density and temperature. • No moving parts for zero maintenance. • Bi-directional flow measurement. • No pressure drop through sensor. • Minimal straight pipe run required. • Every sensor is factory wet-calibrated.