Purge and Pressurized Systems

Bebco EPS® purge and pressurization by Pepperl+Fuchs is a household name in the process automation industry. As the leaders in Purging Technology®, we manufacture innovative solutions that are remarkably simple to use and will easily handle just about any application.

Type X Purge System
The Pepperl+Fuchs Bebco EPS Type X purge system reduces the classification within the protected enclosures from Division 1 to non-hazardous. General-purpose equipment can be operated within the protected enclosure.

Type Y Purge System
The Pepperl+Fuchs Bebco EPS Type Y purging system reduces the classification within the protected enclosure from Division 1 to Division 2. All equipment used within the enclosure must be Division 2 rated.

Type Z Purge System
The Pepperl+Fuchs Bebco EPS Type Z purge system reduces the classification within the protected enclosure from Division 2 to non-hazardous. General-purpose equipment can be operated within the protected enclosure.

Ex px Purge System
The Pepperl+Fuchs Bebco EPS Ex px purge system reduces the classification within the protected enclosure from Zone 1/ Zone 21 to non-hazardous. General-purpose equipment can be operated within the protected enclosure.

Ex pz Purge System
Ex pz purge systems reduce the classification within the protected enclosure from Zone 2 to non-hazardous. General-purpose equipment can be operated within the protected enclosure.

Enviro-Line Pressurization System
Enviro-Line purging units is an enclosure pressurization system for non hazardous areas that operates on a supply of compressed instrument air or inert gas. It regulates and monitors the pressure within the sealed enclosure in order to prevent the accumulation of damaging and caustic gases and dusts.

  • pepperl_fuches_200_85 The 1000 series Type Y purge system is rated for Class I, Division 1 to Division 2 area applications or Class II, Division 1 to Division 2 applications.
    • UL, cUL & FM classified
    • Conforms to NFPA 496 and ISA 12.4 standards
    • Enclosure volumes to 450 cu. ft.
    Note: Vents are required for most Type Y purge enclosures

    Type Y purge system models - 1000 series

    1001A: Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS Only 1001B: Class II Enclosure Volumes ≤ 50 ft3 1001C: Class II Enclosure Volumes ≤ 250 ft3 1002: Class I Enclosure Volumes ≤ 15 ft3 1003: Class I Enclosure Volumes ≤ 75 ft3 1004: Class I Enclosure Volumes ≤ 200 ft3 1005: Class I Enclosure Volumes ≤ 450 ft3 11: Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS and WPSA
  • pepperl_fuches_200_85 The 1000 series Type Z purge system is suitable for Class I, Division 2 to non-hazardous area applications & Class II, Division 2 to non-hazardous area applications.
    • UL, cUL & FM classified
    • Conforms to NFPA 496 and ISA 12.4 standards
    • Enclosure volumes to 450 cu. ft.
    Note: Vents are required for most Type Z purge enclosures

    Type Z purge system models - 1000 series

    1001A: Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS Only 1001B: Class II Enclosure Volumes ≤ 50 ft3 1001C: Class II Enclosure Volumes ≤ 250 ft3 1002: Class I Enclosure Volumes ≤ 15 ft3 1003: Class I Enclosure Volumes ≤ 75 ft3 1004: Class I Enclosure Volumes ≤ 200 ft3 1005: Class I Enclosure Volumes ≤ 450 ft3 11: Class I Enclosure Volumes ≤ 2 ft3 and Class II Enclosure Volumes ≤10 ft3 , WPS and WPSA
  • pepperl_fuches_200_85 Our Pepperl+Fuchs Bebco EPS 3000 series, Type Y or Z / Ex pz purging system will purge and pressurize the protected enclosure and maintain pressure within the enclosure. The system reduces the classification within the protected enclosure from a Zone 2 to non-hazardous area.
    • DEMKO, ATEX, UL,cUL & FM classified
    • Conforms to NFPA 496 and ISA 12.4 EN 50016, and ATEX standards
    • For Type Y, Type Z, and Type pz applications
    • Enclosure volumes to 250 cu. ft.(7.08 cu. m)
    Note: Vents are required for Ex pz purge enclosures

    Type Ex pz purge system models - 3000 series

    3003: Class I Enclosure Volumes ≤ 90 ft3
    3004: Class I Enclosure Volumes ≤ 250 ft3
  • pepperl_fuches_200_85 The Pepperl+Fuchs Bebco EPS 3000 series, Type Y purging system will purge and pressurize the protected enclosure and maintain pressure within the enclosure. The system reduces the classification within the protected enclosure from a Division 1 to a  Division 2 area.
    • UL, cUL & FM classified
    • Conforms to NFPA 496 and ISA 12.4 standards
    • For Type Y or Type Z applications
    • Enclosure volumes to 250 cu. ft.(7.08 cu. m)
    Note: Vents are required for most Type Y purge enclosures

    Type Y purge system models - 3000 series

    3003: Class I Enclosure Volumes ≤ 90 ft3  3004: Class I Enclosure Volumes ≤ 250 ft3
     
  • pepperl_fuches_200_85 The Pepperl+Fuchs 3000 series Type Z purging system will purge and pressurize the protected enclosure and maintain pressure within the enclosure. Suitable for Class 1, Division 2 to non-hazardous and Zone 2 to non-hazardous.
    • DEMKO, ATEX, UL, cUL & FM classified
    • Conforms to NFPA 496 and ISA 12.4 EN 50016, and ATEX standards
    • For Type Y, Type Z, and Type nP applications
    • Enclosure volumes to 250 cu. ft.(7.08 cu. m)
    Note: Vents are required for most Type Z purge enclosures

    Type Z purge system models - 3000 series

    3003: Class I Enclosure Volumes ≤ 90 ft3
    3004: Class I Enclosure Volumes ≤ 250 ft3
  • pepperl_fuches_200_85 The Pepperl+Fuchs 5000Q series Ex pz purge is a small and compact purge system. The 5000Q operates by controlling and monitoring compressed instrument air or inert gas through the protected enclosure(s) to remove and prevent the accumulation of flammable gas, vapors, or dust. It is a powerful purge system designed to meet your Zone 2, 22 installation requirements. The 5000Q series control unit features these main parts:
    • Up to 3 PT100 RTD’s connected for temperature monitoring or control
    • LCD for viewing programming and operation modes
    • Field configurable through menu driven programs for most applications
  • pepperl_fuches_200_85 The Pepperl+Fuchs all-new 5500 Series Ex pz purge and pressurization system is the newest system from Pepperl+Fuchs that provides easy selection, installation, and operation for enclosures located in Zone 2 and 22 hazardous areas. Our Ex pz purge systems are designed according to European requirements—ATEX directive 94/9/EG. European protection methods allow multiple techniques to be used when designing hazardous area equipment.
    • Automatic systems for alarm, purging, and power to enclosure!
    • Built-in programming
    • Programmable temperature control
    • Leakage compensation
  • pepperl_fuches_200_85 The Pepperl+Fuchs all-new 5500 Series Type Z purge and pressurization system is the newest system from Pepperl+Fuchs that provides easy selection, installation, and operation for enclosures located in Division 2 / Zone 2 hazardous areas. The Type Z / Ex pz solutions consist of a control unit, vent, and solenoid valves. The combination of automation and configurable functions support even the most difficult applications.
    • Automatic systems for alarm, purging, and power to the enclosure!
    • Enclosure sizes to 450 cu. ft.
    • Conforms to NFPA 496 and ISA 12.4 standards
    • ATEX, IECEx, and UL certified systems
    • Built-in programming
    • Programmable temperature control
    • Leakage compensation
     
  •   pepperl_fuches_200_85 The Pepperl+Fuchs Bebco EPS 6000 series Type X/ Ex px purging system is a complete automatic system that will purge and pressurize the protected enclosure and maintain pressure within the enclosure. Note: Vents are required for all 6000 series purging systems. The 6000 series purge system reduces the classification within the protected enclosure from Zone 1 and 21 to non-hazardous area. General purpose equipment can be operated within the protected enclosure.
    • Suitable for Class I and II, Division 1/ Zone 1 and Zone 21 to non-hazardous area applications
    • Enclosure sizes up to 450 cubic ft. (12.7 cubic meters)
    • The Type X/ Ex px system conforms to ATEX, NFPA 496 and ISA 12.4
    • DEMKO, UL cULus, IEC Ex
    Download Data Sheet
  • pepperl_fuches_200_85 The Pepperl+Fuchs Bebco EPS 6500 Series Ex px purge and pressurization system provides reliable protection for operating general-purpose electrical equipment in Zone 1/21 explosion hazardous locations. Utilizing the flexible Ex p protection method, the 6500 Series is a fully automatic system. It will purge a common enclosure of hazardous gas or dust and maintain a positive pressure, reducing the classification within the protected enclosure from Zone 1/21 to a non-hazardous area.
    • Suitable for reducing Zone 1/21 hazardous location to a non-hazardous area
    • ATEX/IECEx certification for gas and dust
    • Operates on enclosure sizes up to 12.7 cubic meters (450 cubic ft.)
    • Automatic monitoring and control of enclosure pressure and temperature
    • Remote communication via HART/RS485 and Bluetooth (dedicated smart device app available)
    • Dilution and continuous flow functionality

    Note: Vents are required for all 6500 series purging systems.

  • pepperl_fuches_200_85 The 7500 series system consists of a control unit, an enclosure protection vent, and manual or automatic manifold. The control unit has a touch screen display that is menu driven and will easily guide the user in selecting pre-programmed and user-selected variables. The 7500 can be used with a digital valve/manifold system like the 5500-MAN-... unit to make a fully automatic system. The enclosure pressure and leakage can be monitored and, in the event of a loss in enclosure pressure, the solenoid valve can engage to restore the defined pressure settings and/or alarm for the pressure drop. An easy-to-see display also has 4 LEDs for system condition indication from a distance.

    Features:

    • Low cost, compact design, easy to use
    • Universal power: AC or DC
    • Touch screen display with LEDs for easy visual indication
    • Easy setup with pre-set purge programs for your application
    • Automatic pressure compensation with digital manifold
    • Rugged, corrosion-resistant housing
    • Global third-party approvals for Class I, II, Div. 2 and Zone 2/22
  • pepperl_fuches_200_85 The Pepperl+Fuchs Enviro-Line purging units is an enclosure pressurization system for non hazardous areas that operates on a supply of compressed instrument air or inert gas. It regulates and monitors the pressure within the sealed enclosure at a constant pressure in order to prevent the accumulation of damaging and caustic gases and dusts.
    The elimination of these gases and dusts extends the life of expensive electrical equipment and instrumentation placed within the Enviro-Line purging unit.
    Due to higher pressures inside the electrical enclosure, corrosive environments remain outside. The system maintains a constant 0.5" water pressure inside the enclosure for protection against gas and/or dust.
    • Environmental purge for nonhazardous areas
    • Built in ISO 9001 registered manufacturing facilities
    • Complete package for enclosures up to 7.2 m3 (250 ft3)