Shop

  •   Circulation Heaters Type Ex. Designed for forced flow or natural flow applications. Standard designs ranging from 0.6 to 672kW… higher kWratings are also available.Optional features include built in high limits and thermostats, stainless steel wetted parts. moisture resistant or explosion-proof housings. CRN registered vessels for Canada. Authorized to bear the U and N stamps, depending on ASME code classification (Section VIII or III)
  • moore_logo_200_85 Perfect for Head-Mount Instruments The LH connection heads are ideal for use with head-mount transmitters such as Moore Industries’ TRX/TRY PC-Programmable and THZ2 Smart HART® Temperature Transmitters. The LH heads also protect terminal blocks used for sensor wire terminations.
  • moore_logo_200_85 Moore Industries’ universal PSD PC-Programmable Loop Display features a large integral display that shows real-time process status in mA, percent, or any designated 5-character Engineering units (EGU). Superior Accuracy–The loop-powered PSD reads any 4-20mA signal and displays the information with phenomenal accuracy of ±0.012% of input scale. And because it requires less than 2.3 Volts, it won’t burden most loops. Simple and Versatile PC Setup Program– Using the PC software, the PSD can either be custom scaled to display in a percent or scaled directly into engineering units for indicating process measurements such as pressure, temperature, level, or fl ow. Span, zero, input range, display range, and fi ltering frequency can also be easily programmed. Our software will even capture the input range limits of the loop to provide you with the most accurate display available
  • moore_logo_200_85 Moore Industries’ PAC and PAV Ac Current and Voltage Transducers accept an ac current (PAC) or ac voltage (PAV) input. They provide a highly accurate (±0.25% of rated output) dc current output. The PAC and PAV respond to the average value of the input signal and are calibrated to indicate the RMS value.
  •   moore_logo_200_85 These 2-wire (loop-powered) I/P transmitters accept a current signal (such as 4-20mA) from a DCS, PLC or PC-based control system. They convert the current signal to a pneumatic signal (3-15psig, 0.2-1bar, 20-100kPa, etc.) to provide precise, proportional control of valves, actuators and other pneumaticallycontrolled devices. The economical IPH2 (Type 4X) is watertight, dust-protected, and resistant to corrosion and chemicals. In addition to meeting Type 3X/4X requirements, the IPX2 can be installed in explosionproof environments. Both units are available with an optional coalescing fi lter/regulator that combines an air fi lter and miniature supply line regulator with a pressure gauge that reads in both psig and bars.   Download Data Sheet
  • moore_logo_200_85 Designed specifically for demanding industrial applications, the NET Concentrator System® (NCS) provides a real-time signal gateway between the field or factory floor and your control strategy.
  • moore_logo_200_85 The TRUNKSAFE Fault-Tolerant Fieldbus System provides a cost-effective, yet highly reliable, strategy to maintain continuous communications between field devices and a host system in the event of any single point failure (such as any open single wire) on a FOUNDATION fieldbus™ H1 or PROFIBUS PA segment.
  • moore_logo_200_85 The 330 is a process monitor with universal input that is multi-functional and microprocessor based. The 330 can function as a panel meter and trip (alarm), or as a panel meter with two trips (alarms), analog transmitter and digital transmission with the addition of the RS 485 serial communications option.
  •   moore_logo_200_85 The HIM HART Loop Interface and Monitor unlocks the full potential of new and in-place smart HART multivariable transmitters and valves. Converts HART to 4-20mA Signals The HIM allows up to three additional analog process variable measurements from a smart device with no additional process penetrations or wiring.   Download Data Sheet
  • moore_logo_200_85 The universal SPA2IS Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. Very versatile, they accept signal inputs from transmitters and temperature sensors that are located in hazardous areas where the method of protection implemented by the plant or facility is Intrinsic Safety.
  • moore_logo_200_85 Dual Input Smart HART® Temperature Transmitters configure quickly and easily to accept a direct signal input from a wide array of sensors and analog devices:
  •   moore_logo_200_85 ECT DIN-style signal isolators, converters, repeaters, boosters and splitters feature solid metal housings that stand up to the continuous, daily rigors of process control and factory automation applications. Rugged and reliable, the ECT is available in 2-wire (loop) and 4-wire (line/mains) powered models. The complete family delivers economical solutions for an expansive range of signal interface applications.   Download Data Sheet
Go to Top