Moore Industries’ durable PIH Pressure–to-Current Transmitter provides an economical solution for any process that requires a rugged instrument capable of interfacing a pneumatic device with a data acquisition / control system, controller, recorder or other electronic instrument. This compact yet powerful unit accepts most pneumatic signals (3-15psig, 0.2-1 bar, 3-27 psig etc.) and accurately converts them to a proportional 4-20mA output. -
Moore Industries’ durable PIH Pressure–to-Current Transmitter provides an economical solution for any process that requires a rugged instrument capable of interfacing a pneumatic device with a data acquisition / control system, controller, recorder or other electronic instrument. This compact yet powerful unit accepts most pneumatic signals (3-15psig, 0.2-1 bar, 3-27 psig etc.) and accurately converts them to a proportional 4-20mA output. -
The R-BOX accommodates transmitters, meters, indicators, analyzers, integrators, and many other rail-mounted instruments. The variety of available R-BOX sizes means that we have an R-BOX that will fi t your process needs. Choose from standard internal widths of 3, 6, 9, and 12 inches. Designed to meet Type 4X and IP66 ratings, the R-BOX is resistant to ultraviolet rays and chemicals. Its high-impact structure protects instruments even in harsh fi eld conditions. -
The ALP Series Industrial Hose Pump is a two roller Peristaltic pump designed to handle abrasive slurries, viscous fluids, and aggressive chemicals that are normally difficult to pump with other types of positive displacement technologies. The ALP Series is an ideal choice for metering, batching and transfer applications. Peristaltic pumps are becoming the standard for hard to handle fluids such as Sodium Hypochlorite that off-gas and vapor-lock diaphragm pumps. Self priming high capacity pump can be run dry without damage. Flow rates from 1 to 40 GPM (60 to 2400 GPH). Pressures to 60 psi. -
Series 117P Sanitary Pressure Switch
This field adjustable, compact pressure switch is intended for low- to mid-range process applications. The Tri-Clamp® compatible, polished, process connection makes this switch ideal for food, beverage and other sanitary services. Set point stability and vibration resistance are a function of the Nega-Rate® Belleville disc spring. This unit features 316 stainless steel construction, an explosion-proof/hermetically sealed electrical assembly, 18" standard free leads and SPDT or DPDT electrical forms and a wetted material surface polish of 9 - 11 micro inch Ra (0.23 - 0.28 micron Ra).†
Specifications
• Electrical: Snap action electrical switch listed by Underwriters’ Laboratories, Inc., FM Approval and CSA International
• Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads
• Pressure Connection: 1 1/2" sanitary fitting mates with Tri-Clamp® fitting†
• Temperature Range
o Ambient: -40°F to +180°F (-40°C to +82°C)
o Media: -40°F to +250°F (-40°C to +121°C)
• Adjustment: Internal, slotted adjustment with range scale
• Shipping Weight: Approximately 2 pounds -
The ALH Series of peristatlic pumps provide high levels of volumetric accuracy for sampling and metering applications. ALH Series pumps are available in 15 different sizes that provide flow rates up to 38,000 GPH. The low maintenance, seal-less design eliminates leaks, contamination and wear problems associated with difficult to seal products.
Self priming high capacity pump can be run dry without damage. Flow rates from 0.02 to 387 GPM (1 to 23,220 GPH). Pressures to 217 psi. -
130P NEMA 4 & 13 Pressure Switch/Tamper Resistant
Compact, versatile pressure switch for low to mid-range pressure applications. Features efficient Nega-Rate® Belleville disc spring for stable set points, vibration resistance and field adjustability through the pressure port. Once adjustments are made and switch is installed, it becomes tamper proof.
Specifications
• Electrical: Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International
• Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads
• Pressure Connection: 1/4 NPT Male
• Temperature Range*:
o Ambient: -40°F to +180°F (-40°C to +82°C)
o Media: -40°F to +300°F (-40°C to +149°C)
*Temperature limits change with O-Ring selection
• Adjustment: 1/8" allen wrench through port
• Shipping Weight: Approximately 13 ounces -
182P NEMA 4 & 13 Vacuum Switch / Tamper Resistant
Compact, versatile vacuum switch suited to numerous applications. Features efficient Nega-Rate® Belleville disc spring for stable set points and is field adjustable through the pressure port. Once adjustments are made and switch is installed, it becomes tamper proof.
Specifications
• Electrical: Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International
• Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads
• Pressure Connection: 1/4 NPT Male
• Temperature Range*
o Ambient: -40°F to +180°F (-40°C to +82°C)
o Media: -40°F to +300°F (-40°C to +149°C)
• Adjustment: 1/8" allen wrench through port
• Shipping Weight: Approximately 8 ounces
*Temperature limits change with O-Ring selection -
When Hydrogen purity drops, windage losses and operating costs increase, resulting in lost revenue and profitability. Gas purity is also a critical life safety issue, making monitoring for potentially explosive levels essential. E/One's Hydrogen Control Cabinet (HCC) was designed specifically for monitoring and controlling hydrogen purity in GE generators that utilize scavenging seal oil systems. The HCC contains two independent analyzers that monitor hydrogen purity from both the turbine-end seal drain enlargement and the collector-end seal drain enlargement. Designed to be used in a hazardous location, the HCC has the ability to automatically increase the amount of hydrogen gas bled from the generator. It's also an easy replacement for your old hydrogen control cabinet. Featuring digital displays, warnings and alarms, the HCC works with all GE and non-GE control systems.