Shop

  • moore_logo_200_85 The rugged IPF Field-Mounted Current-to-Pressure Transmitter is designed specifically for installation in harsh environments. The two-wire IPF accepts a 4-20mA or 10-50mA input. It converts the input to a 3-15psig, 0.2-1bar, 15-3psig or 1-0.2bar pneumatic output signal, or to a wide variety of other commonly used pneumatic outputs (see Specifications for details). This versatility allows the IPF to interface with just about any kind of process control instrumentation including chart recorders, data loggers, panel meters, multiplexers, controllers and computers. The IPF can either be surface-mounted or mounted directly on a two-inch (vertical or horizontal) pipe. Two different types of housings are offered. The standard WP housing provides 1/2-inch NPT female wire entry threads while the metric WPM housing provides M20X1.5 female wire entry threads. The IPF transmitter is also available with an optional coalescing filter/regulator that combines both an air filter and a miniature supply line regulator. For more information on
  • moore_logo_200_85 The D-BOX® accommodates temperature, pressure, level and fl ow transmitters, meters, indicators, analyzers, integrators, and many other head-mount and hockey-puck instruments.
  •     DXC Over-The-Side Immersion Heaters feature copper sheathed elements and are typically used for heating water or water solutions that will not corrode copper. They are ideal where easy removal of the heater for cleaning or inspection is required. The DXC is available in single phase or three phase with single element or three element configurations. DXI Over-The-Side Immersion Heaters feature incoloy® sheathed elements, while the DXS features steel sheathed elements. They are typically used in water rinse tank heating applications where contaminants that would be corrosive to copper are present. They are also suitable for oil based solutions and other chemical solutions that are not corrosive to incoloy® (DXI) or steel (DXS). They are ideal where easy removal of the heater for cleaning or inspection is required. The DXI and DXS are available in single phase or three phase with single element or three element configurations. DXN and DXT Over-The-Side Immersion Heaters feature high grade inconel® (DXN) or titanium (DXT) sheathed elements and are typically used in liquid heating applications where copper, stainless or incoloy® are unsuitable because the solution being heated would be corrosive to these materials. They are ideal where easy removal of the heater for cleaning or inspection is required. The DXN is available in single phase or three phase with single element or three element configurations and the DXT is available in single phase with single element configuration
  • flomotion_logo_200_85 2001V Series Peristaltic Pump Systems INDUSTRIAL HOSE PUMP. Exceptional self-priming capabilities make the 2001V Series an ideal choice for hard-to-handle chemicals such as sodium hypochlorite, hydrogen peroxide or viscous polymers. Flow rates to 50.2 gallons per hour.
  • eastech_logo_200_85 The Vantage 2200 is a state-of-the-art microprocessor-based ultrasonic transmitter utilized for measurement of both liquid level and flow in open channels. The 2200 is equipped, as standard, with an internal data logger. More than 70 standard flow equations for flumes, weirs and open flow nozzles are stored in non-volatile memory. Dual sensors can be input to a single set of electronics for dual weir/flume or bar screen level applications. The Vantage 2200 is designed to be extremely user-friendly with an easy to read 20 character alphanumeric, self-prompting display and a menu-driven programming guide.
  • fluidwell_200_85 The D013 is a versatile, panel mount flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the facility to set one low flow rate and one high flow rate alarm value. If desired, a delay function can be set up to allow for an incorrect flow rate for a certain period of time.
  • fluidwell_200_85 The D016 is a local panel mount indicator / transmitter with linearization to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however cannot be reset to zero. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range. Even for very low frequency applications is catered for. This linearization affects all displayed information as well as the pulse output.
  • fluidwell_200_85 he D030 is a straight forward but basic, panel mount batch controller. The operator can enter a batch quantity easily or execute repeating batches. During the batch, the preset value is displayed as well as the batched (or remaining) quantity and the units of measurement. The automatic self-learning overrun correction will ensure an accurate result each batch again.
  • fluidwell_200_85 The F093 is a local indicator to monitor the tachometer engine speed with running hours simultaneously. The running hours can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated running hours however cannot be reset to zero.
  • itt_logo_200_85 232P NEMA 4X, 7, 9 & 13 Pressure Switch/Internal Adjustment Compact, adjustable pressure switch for high pressure hydraulic process applications. Efficient Nega-Rate® Belleville disc spring for set point stability and vibration resistance. Stainless steel wetted materials and hermetically sealed, explosion proof electricals make this switch ideally suited for hazardous and corrosive media or environments. Specifications • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads • Pressure Connection: 1/4 NPT Female • Temperature Range* o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +250°F (-40°C to +121°C) • Adjustment: Internal, slotted adjustment nut with range scale • Shipping Weight: Approximately 20 ounces
  • itt_logo_200_85 180P NEMA 4 & 13 Vacuum Pressure Switch/Internal Adjustment Adjustable vacuum switch with efficient Nega-Rate® Belleville disc spring sensing mechanism. Weather proof enclosure and stable set points makes this switch ideal for a wide variety of applications. Specifications • Electrical: Snap action electrical switch recognized by Underwriters’ Laboratories, Inc. and CSA International • Electrical Connection: 1/2 NPT female conduit connection with terminal block • Pressure Connection: 1/4 NPT Female • Temperature Range* o Ambient: -40°F to +180°F (-40°C to +82°C) o Media: -40°F to +250°F (-40°C to +121°C) • Adjustment: Concealed wrench flat adjustment with range scale • Shipping Weight: Approximately 3.5 pounds *Temperature limits change with O-Ring selection
  • itt_logo_200_85 132TC Temperature Switch/Internal Adjustment Compact, adjustable temperature switch featuring the efficient Nega-Rate® Belleville disc spring for set point stability and vibration resistance. Available with all stainless steel exterior and interior construction together with a hermetically sealed, explosion-proof electrical assembly. Ideally suited for applications involving hazardous and corrosive medias or environments. Comes with capillary for remote mount up to 25 feet. Specifications • Electrical: Snap action electrical switch assembly listed by Underwriters’ Laboratories, Inc., FM Approval and CSA International • Electrical Connection: 1/2 NPT male conduit connection with PVC insulated 18 AWG, 18" long leads • Process Connection: 1/2 NPT Male Remote mount Stainless steel 6' capillary with armor jacket, 10" minimum bendable tubing and 1/2" adjustable gland nut. Optional capillary lengths available. • System Pressure: 1500 psig maximum • Proof Pressure: 2250 psig • Adjustment: Internal, slotted adjustment nut with range scale • Temperature Range: o Ambient: -40°F to +180°F (-40°C to +82°C) o See Electrical Assembly specification sheet for Temperature Class Ratings. • Shipping Weight: Approximately 3.5 pounds
Go to Top