The F153 is a versatile pressure indicator featuring continuous pressure monitoring. It offers the ability to set two low and two high pressure alarm values. If desired, an ignore function can be set up to allow for an incorrect temperature for a certain period of time. Up to five outputs are available to transmit alarm conditions and actual pressure. The display shows the actual pressure, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.
-
The F114 flow computer calculates the actual ratio between two separate flows. It offers the ability to set one low ratio and one high ratio alarm value. Special precautions are taken to allow start-up problems and incorrect ratio readings for a certain period of time. Based on the location of the flow meters, a selection can be made out of six different formulas. The display shows the ratio, alarm values, flow rate A, total A and flow rate B, total B. On-screen engineering units are easily configured from a comprehensive selection. The ratio can be displayed as 1:__ or as a percentage.
-
The F197 is a manual set-point generator. The operator enters an analog or a scaled output value or a percentage which will be transmitted as a (0)4 – 20mA or 0 – 10V DC signal to a control device. If available, the F197 can also display the measured actual process value. However, there is no direct control relationship between the input and output value. Further, one low and one high alarm value can be set with an alarm ignore function to monitor the process. The display shows the pre-set value, actual value and status simultaneously. On-screen engineering units are easily configured from a comprehensive selection.
-
The F040 is a straight forward temperature indicator with large 26mm (1") high digits. The measuring unit to be displayed below the temperature is simply selected through an alphanumeric configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user-friendly solution! The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive DIP-switches or trimmers.
-
The F195 has been developed for the valve position indication and monitoring in hydraulic systems. By using a bi-directional flow meter to measure the volume displaced by the actuator, an accurate position of the system is calculated. The display shows the position as a percentage as well as with the text "open" and "closed" for the minimum and maximum positions. As standard, the analog output mirrors the percentage displayed which can be used to transmit the valve position. The usual difficulties encountered in such applications include: very low flows, vibration, and thermal expansion of the oil and high ambient temperatures.
-
CXC Flange Heaters are used primarily for water heating applications and feature copper sheathed elements silver brazed to a steel flange. CXI Flange Heaters are well suited for heating water, especially in hot water and steam boilers, as well as heating mildly corrosive solutions in rinse tanks, spray washers, etc. The heater features incoloy® sheathed elements silver brazed to steel flange. CXF Flange Heaters are used primarily for heating applications involving oils, gases and mildly corrosive liquids. They are constructed of incoloy® sheathed elements silver brazed to a steel flange.
-
FMS Series electromagnetic flow meter easily connects too many common controllers. Economical small-diameter flow sensors for reliable full-pipe flow measurement with low-cost and fast installation. FMS05 / FMS10 / FMS20 FEATURES • Accuracy to +/-2.0% • Flows from 0.5 to 951 GPH • Pressures to 145 PSI • Fluid temperatures to 140 F • Compatible with pulsating flows • Easy to install union end connections • Outputs: Pulse, Error, Alarm.
-
The E/One Gas Station is a modular approach that combines monitoring and control systems onto a single skid, customized to meet specific power plant requirements and budgets. Gas Station modules include: • Main gas supply manifold and associated controls • Gas purity monitoring • Overheat monitoring • Dew point monitoring • Gas drying • Partial discharge monitoring • Seal oil system monitoring and control • Customized annunciator panels
-
Conoflow’s Pneumatic Piston Actuators are compact units designed to function in today’s high performance instrument systems. Piston diameters of 3” to 12.5” are available with standard strokes up to 10” (for stroke lengths greater than 10”, consult the factory). Integral positioners are standard for modulating service.Force produced is a function of the supply pressure which can be varied from 20 to 100 PSI (138 to 690 kPa). Fast stroking speeds are made possible through the use of a high capacity positioner coupled with a unique cushion-loading regulator. The GB50 Series Piston Actuators are designed for use in corrosive atmospheres or adverse weather conditions.