Fluidwell

  • fluidwell_200_85 The D053 is a versatile, panel mount pressure indicator with continuous pressure monitoring feature. It offers the facility to set one low pressure and one high pressure alarm value. If desired, an ignore function can be set up to allow for an incorrect pressure for a certain period of time. Advantages Unique, robust IP66, IP67 (Type4X) panel mount front enclosure made of die cast aluminum, allowing even big jets of water and total immersion. Programming can be done by your own crew with the exact same, plain and sensible menu-driven structure like the F-Series, saving cost and irritation. Know one, know them all!
  • fluidwell_200_85 The F173 is a versatile level indicator featuring linearization and continuous level monitoring. In addition to the average Span, fifteen linearization points can be entered to compensate for the tank shape. The unit will interpolate between these points to increase accuracy. This linearization affects all displayed information as well as the alarm and analog outputs. With the level monitoring feature, two low and two high level alarm values can be set. If desired, an ignore function can be set up to allow for an incorrect level for a certain period of time. Up to five outputs are available to transmit alarm conditions and actual level. The display shows the actual level, height or percentage, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.
  • fluidwell_200_85 The F193 is a versatile large digit Modbus display. All displayed information and signal outputs are controlled through the Modbus ASCII / RTU communication protocol. Information of nine different tanks or products can be displayed with an automatic toggle function or can be selected by the operator. Of course, it can also be selected and locked through communication. Further, up to four control or alarm outputs can be controlled directly or being linked to an alarm status of the nine products: an alarm message will be displayed and the related relay(s) switched. Also available is an analog output signal, fully controlled through the communication. For security reasons, all outputs can be switched-off automatically in case of a communication break-down. The display shows the actual value, product / tank ID, measuring unit, alarm messages and status.
  • fluidwell_200_85 The F018 is a local indicator / transmitter with linearization that displays the actual flow rate, resettable total and non-resettable accumulated total. The F-Series is known worldwide as a range of user-friendly indicators. The F018 is even more impressive. The HART communication allows you to communicate in an easy way with smart "DD enabled host" systems. In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range, even for very low frequency applications. This linearization affects all displayed information as well as the signal outputs.
  • fluidwell_200_85 The E018 is one of the top models in our range of explosion proof flow computers. In addition to the average K-Factor, 16 linearization points can be entered. The unit will interpolate between these points greatly enhancing accuracy in any flow range. Moreover, a continuous flow rate monitoring feature is available with high and low flow rate alarm values and four alarm outputs.
  • fluidwell_200_85 The D074 is a basic, panel mount level / pump controller that works with a pre-set value and two switch points to control a pump or valve. The low and high level switch points are entered as a percentage of the pre-set value to switch the device on / off. For pump control applications, the function can be inverted to empty a well. A stable level within a hysteresis around the pre-set value is the result.  
  • fluidwell_200_85 The D040 is a straight forward, panel mount temperature indicator. The measuring unit to be displayed is simply selected through an alfa-numerical configuration menu. No adhesive labels have to be put on the outside of the enclosure: a weather proof and user friendly solution! The configuration of the Span, off-set and number of decimals is done through software functions, without any sensitive dip-switches or trimmers. Advantages Unique, robust IP66, IP67 (Type4X) panel mount front enclosure made of die cast aluminum, allowing even big jets of water and total immersion. Programming can be done by your own crew with the exact same, plain and sensible menu-driven structure like the F-Series, saving cost and irritation. Know one, know them all!
  • fluidwell_200_85 The F153 is a versatile pressure indicator featuring continuous pressure monitoring. It offers the ability to set two low and two high pressure alarm values. If desired, an ignore function can be set up to allow for an incorrect temperature for a certain period of time. Up to five outputs are available to transmit alarm conditions and actual pressure. The display shows the actual pressure, alarm values, alarm messages and status. On-screen engineering units are easily configured from a comprehensive selection.
  • fluidwell_200_85 The D074 is a basic, panel mount level / pump controller that works with a pre-set value and two switch points to control a pump or valve. The low and high level switch points are entered as a percentage of the pre-set value to switch the device on / off. For pump control applications, the function can be inverted to empty a well. A stable level within a hysteresis around the pre-set value is the result.  
  • fluidwell_200_85 The F195 has been developed for the valve position indication and monitoring in hydraulic systems. By using a bi-directional flow meter to measure the volume displaced by the actuator, an accurate position of the system is calculated. The display shows the position as a percentage as well as with the text "open" and "closed" for the minimum and maximum positions. As standard, the analog output mirrors the percentage displayed which can be used to transmit the valve position. The usual difficulties encountered in such applications include: very low flows, vibration, and thermal expansion of the oil and high ambient temperatures.
  • fluidwell_200_85 The D013 is a versatile, panel mount flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the facility to set one low flow rate and one high flow rate alarm value. If desired, a delay function can be set up to allow for an incorrect flow rate for a certain period of time.
  • fluidwell_200_85 The D016 is a local panel mount indicator / transmitter with linearization to display the actual flow rate, total and accumulated total. The total can be reset to zero by pressing the CLEAR button twice. The eleven digit accumulated total however cannot be reset to zero. In addition to the average K-Factor or Span, eight linearization points can be entered with their frequencies or values. The unit will interpolate between these points greatly enhancing accuracy in any flow range. Even for very low frequency applications is catered for. This linearization affects all displayed information as well as the pulse output.