Shop

  • adroid_logo_200_85 Adroit Smart SCADA System designed for process control, manufacturing systems and open automation applications. Adroit 8.0 is developed on the .NET platform and is compatible with various Microsoft operating systems. Adroit 8.0 has a flexible, object-oriented, client server architecture that supports any system from a stand-alone implementation to an installation spanning multiple distributed sites. Adroit is built on a client-server architecture, where the Agent Server (I/O Server) communicates with field devices and performs the Server functions of scanning, logging, alarming and value processing. The Client side (Classic and Smart User lntefaces) provides the capability of configuring, displaying, manipulating and delivering the values in a rich, secure user interface.    
  • moore_logo_200_85
    The SIL 2 and SIL 3 capable STZ Functional Safety Dual Input Smart HART® Temperature Transmitters for your SIS (Safety Instrumented System) confi gures quickly and easily to accept a single or dual input from a wide array of sensors and analog devices:
    • 14 RTD Types
    • 9 Thermocouple Types
    • Resistance and Potentiometer Devices
    • Direct Millivolt Sources
    These 2-wire (loop-powered) transmitters provide an isolated and linear 4-20mA output proportional to the input. This signal is ready for direct interface with HART or non-HART based Safety System, DCS, PLC and other computer-based SCADA systems. FMEDA (Failure Mode Effects and Diagnostic Analysis) reports are available with the required safety data to ensure that the STZ meets the requirements of each Safety Instrumented Function (SIF).

    Features:

    • STZ-DIN   Functional Safety Dual Input Smart HART® Temperature Transmitter now includes associated Intrinsically-Safe Sensor Connections. The intrinsically–safe –AIS option allows direct connection of sensors located in Non-Hazardous or Class 1, Division 2/Zone 2 hazardous locations  with sensor input terminals connected to equipment or sensors located in Class I , II III, Division 1 /Zone 0/1 hazardous locations since it includes an internal intrinsically-safe barrier in the front end of the THZ3.
    • exida certifi ed to IEC 61508:2010. Certified by exida to IEC 61508 for systematic integrity up to SIL 3 and for random integrity up to SIL 2. This means that an STZ is approved for single use in Safety Instrumented Systems (SIS) up to SIL 2 and in a redundant architecture (1oo2, 2oo3, etc.) up to SIL 3.
    • Comprehensive FMEDA certified safety data. Upon request, exida-certified FMEDA data is available for a functional safety practitioner to use in determining the STZ applicability in specific safety-related applications.
    • Dual sensor input for Backup and Failover Protection, Average and Differential measurement and Low or High Select.
    • Device Intelligence including Sensor Drift and Corrosion Detection, Smart Range Alarms, High-availability option, and Input Simulation capability.
    • HART 7 compliant with exception-based reporting and dynamic variable mapping.
    • HART Access Control. To prevent unauthorized or accidental reconfiguration of the STZ while it's performing it's safety function, it has an added security feature to allow users to set HART communication into a Read Only or Off mode.
    • Input-to-output analog accuracy of up to ±0.014°C (±0.025°F)* is the absolute best in the industry.
    • 20-bit input resolution delivers exceptional digital accuracy of ±0.1°C (±0.18°F) with all Pt RTDs or up to ±0.05°C (±0.09°F)* for Pt1000 RTDs.
    • HART & DTM Programmable with user-oriented basic configuration for fast and accurate setup. HART configurable via any HART handheld configurator or HART compatible host. Additionally program or monitor with any FDT compliant host or program, such as PACTware, utilizing our DTM.
    • Long-term stability provides up to 5 years between scheduled calibrations.
  •   moore_logo_200_85 ECT DIN-style signal isolators, converters, repeaters, boosters and splitters feature solid metal housings that stand up to the continuous, daily rigors of process control and factory automation applications. Rugged and reliable, the ECT is available in 2-wire (loop) and 4-wire (line/mains) powered models. The complete family delivers economical solutions for an expansive range of signal interface applications.   Download Data Sheet
  • moore_logo_200_85 Dual Input Smart HART® Temperature Transmitters configure quickly and easily to accept a direct signal input from a wide array of sensors and analog devices:
  • moore_logo_200_85 The universal SPA2IS Programmable Limit Alarm Trips provide on/off control, warn of unwanted process conditions, alarm on rate-of-change and provide emergency shutdown. Very versatile, they accept signal inputs from transmitters and temperature sensors that are located in hazardous areas where the method of protection implemented by the plant or facility is Intrinsic Safety.
  •   moore_logo_200_85 The HIM HART Loop Interface and Monitor unlocks the full potential of new and in-place smart HART multivariable transmitters and valves. Converts HART to 4-20mA Signals The HIM allows up to three additional analog process variable measurements from a smart device with no additional process penetrations or wiring.   Download Data Sheet
  • moore_logo_200_85 The 330 is a process monitor with universal input that is multi-functional and microprocessor based. The 330 can function as a panel meter and trip (alarm), or as a panel meter with two trips (alarms), analog transmitter and digital transmission with the addition of the RS 485 serial communications option.
  • moore_logo_200_85 The TRUNKSAFE Fault-Tolerant Fieldbus System provides a cost-effective, yet highly reliable, strategy to maintain continuous communications between field devices and a host system in the event of any single point failure (such as any open single wire) on a FOUNDATION fieldbus™ H1 or PROFIBUS PA segment.
  • moore_logo_200_85 Designed specifically for demanding industrial applications, the NET Concentrator System® (NCS) provides a real-time signal gateway between the field or factory floor and your control strategy.
  •   moore_logo_200_85 These 2-wire (loop-powered) I/P transmitters accept a current signal (such as 4-20mA) from a DCS, PLC or PC-based control system. They convert the current signal to a pneumatic signal (3-15psig, 0.2-1bar, 20-100kPa, etc.) to provide precise, proportional control of valves, actuators and other pneumaticallycontrolled devices. The economical IPH2 (Type 4X) is watertight, dust-protected, and resistant to corrosion and chemicals. In addition to meeting Type 3X/4X requirements, the IPX2 can be installed in explosionproof environments. Both units are available with an optional coalescing fi lter/regulator that combines an air fi lter and miniature supply line regulator with a pressure gauge that reads in both psig and bars.   Download Data Sheet
  • moore_logo_200_85 Moore Industries’ PAC and PAV Ac Current and Voltage Transducers accept an ac current (PAC) or ac voltage (PAV) input. They provide a highly accurate (±0.25% of rated output) dc current output. The PAC and PAV respond to the average value of the input signal and are calibrated to indicate the RMS value.
  • moore_logo_200_85 Moore Industries’ universal PSD PC-Programmable Loop Display features a large integral display that shows real-time process status in mA, percent, or any designated 5-character Engineering units (EGU). Superior Accuracy–The loop-powered PSD reads any 4-20mA signal and displays the information with phenomenal accuracy of ±0.012% of input scale. And because it requires less than 2.3 Volts, it won’t burden most loops. Simple and Versatile PC Setup Program– Using the PC software, the PSD can either be custom scaled to display in a percent or scaled directly into engineering units for indicating process measurements such as pressure, temperature, level, or fl ow. Span, zero, input range, display range, and fi ltering frequency can also be easily programmed. Our software will even capture the input range limits of the loop to provide you with the most accurate display available