- All Plastic Design
- Excellent Chemical Resistant
- No Pressure Drop
Featues:
- Senses Liquid through Tubing
- Tubing Size ¼” to ½”
- Flow / No Flow
- Non-Intrusive
- Air Bubble Detection
- All Plastic Design
- Simple to Install
- Heavy Walled Tubing / Up to 0.062″
- Lightweight
- Very Accurate / Sensitivity Adjustment
- Perfect for Dosing or Metering Pumps
Specifications:
Applicable Pipes Size 3/8 – ½” / (7 to 13 mm)
Materials PolyCarbonat
Wall thickness 0.62″
Sensing Object Liquid
Sensing methods Electrostatic Capacitive / Photoelectric
Repeat Accuracy ±0.2 mm max.
Power Supply 12 to 24VDC /10% max. ripple / (10.8 to 30VDC)
Current Consumption 12mA max.
Relay Output Load current /NPN / PNP (100mA max) Residual voltage 1V max. (Load current: 100mA
Indicators Detection indicator (orange)
Ambient Temperature Range Operating: 0 to 55°C (with no icing or condensation), Storage: -10 to 65°C (with no icing or condensation)
Ambient Humidity Range Operating/Storage: 25% to 85% (with no condensation)
Materials PolyCarbonat
Wall thickness 0.62″
Sensing Object Liquid
Sensing methods Electrostatic Capacitive / Photoelectric
Repeat Accuracy ±0.2 mm max.
Power Supply 12 to 24VDC /10% max. ripple / (10.8 to 30VDC)
Current Consumption 12mA max.
Relay Output Load current /NPN / PNP (100mA max) Residual voltage 1V max. (Load current: 100mA
Indicators Detection indicator (orange)
Ambient Temperature Range Operating: 0 to 55°C (with no icing or condensation), Storage: -10 to 65°C (with no icing or condensation)
Ambient Humidity Range Operating/Storage: 25% to 85% (with no condensation)
Ambient Humidity Range Operating/Storage: 25% to 85% (with no condensation)
Temperature Influence ±4 mm of detection level at 23°C in the temperature Range of 0 to 55°C (with pure water or 20% saline solution)
Voltage Influence ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range
Insulation Resistance 50 M Ohm min. (at 500VDC) between current-carrying parts and case
Dielectric Strength 500VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration Resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock Resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of Protection IP66 (IEC)
Connection Method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 70 g
Temperature Influence ±4 mm of detection level at 23°C in the temperature Range of 0 to 55°C (with pure water or 20% saline solution)
Voltage Influence ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range
Insulation Resistance 50 M Ohm min. (at 500VDC) between current-carrying parts and case
Dielectric Strength 500VAC, 50/60 Hz for 1 min between current-carrying parts and case
Vibration Resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock Resistance Destruction: 500 m/s2 3 times each in X, Y, and Z directions
Degree of Protection IP66 (IEC)
Connection Method Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 70 g